01Popricani, Iași · Est. 1998

Precision thermal infrastructure.Built for Europe.

EN 253 pre-insulated piping systems manufactured since 1998. Engineered for 30+ years of district heating service.

Configure RFQ

03Product range

Seven assemblies. One catalogue of sizes.

Rotate, x-ray and resize each assembly. Every dimension below comes from the catalogue table.

Pre-insulated pipe

Straight bonded pipe. 6 m and 12 m delivery lengths, other lengths on request.

Insulation series

* S2, S3: on request

Length
on request
Steel
219.1 × 4.5
Casing
315 × 4.1
Insulation
43.9 mm
Heat loss at 80 °C
31.9 W/m
Pre-insulated pipe
Length 12 m
Full catalogue (PDF)

STEP models are issued with the quotation.

04Record and corridors

Record

28
years manufacturing, since January 1998
1,000+
projects delivered (company record)
DN800
largest carrier, from DN15
4
EN standards the system is built to

SR EN 253 · SR EN 448 · SR EN 489 · SR EN 14419

Bucharest≈400 km · 1 dayVienna≈1,100 km · 2 daysWarsaw≈1,250 km · 2–3 daysMunich≈1,500 km · 3 daysParis≈2,350 km · 4 daysFactory · Popricani, Iași
Road corridors from PopricaniIndicative door-to-door road transit, dedicated truck. Confirmed per order.

05Thermal performance

What thirty years cost through the wall.

Choose a size and a flow temperature. The page computes the steady-state loss of a single buried pipe for each insulation series.

S1Insulation series
168.3 / 250
37.3 mm PUR
29.3 W/m
7,701 MWh
Loss per km over 30 years
S2Insulation series
168.3 / 280
51.9 mm PUR
23.1 W/m
6,064 MWh
-21 % vs Series 1
S3Insulation series
168.3 / 315
69.3 mm PUR
18.9 W/m
4,961 MWh
-36 % vs Series 1

Method: resistances of foam, casing and soil in series (EN 13941 approach). λ foam 0.027, soil 1.5 W/mK, cover 0.8 m, soil 8 °C. Illustrative, not a design calculation.

06Certificate register

Certificate register

The standards each product line is manufactured and tested against. Copies are issued with every quotation.

ReferenceScopeDocument
SR EN 253:2004Bonded pre-insulated pipe systems: steel service pipe, PUR insulation, PE casingIssued on request
SR EN 448Pre-insulated fitting assembliesIssued on request
SR EN 489Joint assemblies for steel service pipesIssued on request
SR EN 14419Surveillance systems, compact or modularIssued on request
Integrated management systemCertificate, recertified 2021View copy
Technical approvalAgrément tehnic for pre-insulated systemsView copy

07Issue for quotation

Issue for quotation

Five fields of engineering, one of contact. A technical reply comes from the export desk, not a sales script.

Mon to Fri, 08:00 to 17:00 EET

Which assemblies does the project need?
Insulation series
Design pressure

Confirmed against the carrier wall in the quotation.